EP SERIES / HELIUM / TWO-POSITION TWO-WAY
Two Helium Valves, Two Different Selection Points
Choose EP6501-00 when the requirement centers on a 22.5 MPa working-pressure rating and a 10.8 g valve. Consider EP6502-00 for a helium circuit specified around its 0.25 mm nominal flow diameter and 4.5 MPa working pressure. Both are 5 V DC miniature solenoid valves with a normally closed, two-position two-way function.
EP6501-00: 0.1 mm Flow Passage, 10.8 g

EP6501-00: the drawing shows a 28.9 mm axial dimension, an 8.50 mm cylindrical body diameter and a 12.00 mm flange diameter.
The 0.1 mm nominal flow diameter belongs to the internal fluid path, not the outside body diameter. The compact outline makes this model a useful starting point where the helium valve must fit a tightly constrained mounting space. Check the complete connection and retention details against the equipment interface before selection.
EP6502-00: 0.25 mm Passage with Flange Mounting

EP6502-00: threaded-end and flange views show the installation arrangement; dimensions are in mm.
This 65 g model has its own mounting geometry and 4.5 MPa working-pressure specification. Its larger nominal passage is a flow-path characteristic, not evidence of a higher pressure rating or a guaranteed flow multiple compared with EP6501-00. Allow space for the flange, fasteners, electrical leads and mating connection.
Side-by-Side Catalog Data
| Parameter | EP6501-00 | EP6502-00 |
| Working medium | Helium | Helium |
| Nominal flow diameter | 0.1 mm | 0.25 mm |
| Working pressure | 22.5 MPa | 4.5 MPa |
| Fluid temperature | -55 to +135 °C | -55 to +135 °C |
| Supply voltage | 5 V DC | 5 V DC |
| Working current | ≤0.2 A | ≤0.2 A |
| Valve function | 2/2-way, normally closed | 2/2-way, normally closed |
| Mass | 10.8 g | 65 g |
Specify the Helium Duty at Both Ports
For a meaningful flow assessment, give helium inlet pressure, downstream pressure, gas temperature and the required mass flow or volumetric flow with its reference conditions. State whether pressure values are gauge or absolute. Required switching differential, reverse pressure and trapped downstream pressure need separate review from the body working-pressure rating.
Define closed-state leakage with a test pressure, temperature, unit and test medium. Internal seat leakage and leakage to atmosphere are different acceptance items. If a tracer-gas leak method is required, include its method and acceptance threshold in the inquiry.
What the 5 V / 0.2 A Figures Mean
Both models specify 5 V DC and working current no greater than 0.2 A. At 5 V and 0.2 A the electrical input is 1 W; this calculation does not establish coil inrush, a peak-and-hold waveform or continuous-duty approval. Supply tolerance, cable voltage loss, maximum on-time and repetition rate belong in the driver review.
The -55 to +135 °C range is the specified helium temperature. Provide the ambient temperature around the coil separately. For timed switching, state the required opening and closing intervals and how the fluid output is to be measured.
A Filter Option for the 0.1 / 0.25 mm Fluid Path
MH can engineer a sintered stainless steel filter into a custom helium-valve configuration. Sintered wire mesh or sintered fiber felt, supporting parts and sealing interfaces are matched to the protected small passage. These are custom options rather than features assigned to the two catalog models.
Define the particle-retention requirement together with helium flow and allowable pressure loss. A filter selected only by nominal retention may have insufficient area for the duty. Assess loading across the filter independently of valve-body pressure, and specify how the integrated element will be accessed or replaced.

Precision machining workshop supporting valve-body and mounting-feature production.
Acceptance Checks for an EP Supply
Model selection should lead to a defined delivery specification: outline and interface dimensions, the required port function, pressure integrity, helium sealing criteria and electrical actuation. MH performs applicable routine outgoing electrical-valve checks, including current/resistance, pull-in/release voltage and flow/pressure-drop checks, alongside dimensional and pressure verification.

Gas-pressure test equipment. Test medium, pressure sequence and sealing limits follow the selected valve specification.

Test-station operation supports functional acceptance to the agreed product requirements.
Ask for EP6501-00 or EP6502-00
Send the model, quantity, mounting sketch, helium inlet/outlet conditions, flow and leakage targets, and the intended 5 V operating cycle. For a filtered variant, add the cleanliness objective and available space. MH can review an interface-based variant without requiring you to prepare the internal valve drawings.
Request EP Series Technical Review
Other functions or a different package? Explore complete valve development.
Hot Tags: miniature high pressure solenoid valve, high pressure gas solenoid valve, high pressure solenoid valve, helium solenoid valve, 4mm Solenoid Valve 2 2 Way Normally Closed , directional control valve solenoid, fuel solenoid valve, miniature high pressure solenoid valve, solenoid control, solenoid valve air filter