Micro Relief Valve
HYDRAULIC PRESSURE LIMITING / MINIATURE & CARTRIDGE DESIGNS
Relief Valves Matched to Pressure and Bypass Flow
MH supplies compact hydraulic pressure relief valves for valve blocks, hydraulic power units, test equipment and custom control circuits. Miniature cartridges and larger hydraulic configurations provide different installation envelopes and flow capacities.
A relief valve must pass the required bypass flow while keeping circuit pressure within the intended limit. Define the opening point, pressure at relieving flow, outlet back pressure and reseat behavior together.
Compact Circuits and OEM Assemblies
Product examples below include 2.5 mm cartridge valves, 4 mm compact relief valves and 10 mm hydraulic configurations. MH also undertakes custom relief-valve development from the installation interface, pressure-flow duty and acceptance requirements, without requiring internal part drawings.
Specify the Complete Relieving Cycle
Opening point
Define the flow threshold used to identify opening, the fluid temperature and the permitted pressure tolerance. A pressure described as the working pressure is not automatically the cracking or set pressure.
Pressure at the required relief flow
As flow increases, the pressure needed to pass it can rise above the opening point. Specify the maximum permissible circuit pressure at the actual bypass flow, not only the initial opening value.
Closure after pressure falls
Reseat pressure and leakage after reseating affect how the circuit recovers. The opening and closing points can differ; the acceptable pressure band should be defined for the operating cycle.
An Opening / Closing Example
AQF3-0200 has a specified opening pressure of 9.3 ±0.3 MPa and closing pressure ≥8 MPa, with 9.8 MPa working pressure and 1.3 L/min flow. The values describe its hydraulic duty and opening/closing window.
Match the Duty to the Valve Format
Small cartridges and larger hydraulic relief configurations address different pressure-flow and packaging needs. The figures below belong to their individual model; flow values do not define a universal pressure-flow curve.
Miniature and Cartridge Relief Elements
| Compact Model | Individual Design Reference |
|---|---|
| YLF4-0200 Cartridge relief |
2.5 mm bore; No. 15 aviation hydraulic oil; -55 to +135 °C; opening pressure ≥21 MPa; flow ≥1.5 L/min. |
| YLF4-0201 Opening-pressure variant |
Specified opening-pressure range: 20-20.5 MPa. |
| YLF6-0201 High-pressure miniature |
2 mm bore; hydraulic oil; working pressure 44.5 MPa; -55 to +70 °C; flow 10.8 L/min; mass ≤8 g. |
| AQF5-0201 Small hydraulic relief |
2 mm bore; No. 15 aviation hydraulic oil; working pressure 22.5 MPa; -55 to +70 °C; flow 1.3 L/min; mass ≤8 g. |
Compact Pressure-Range Options
| Series Reference | Pressure and Temperature |
|---|---|
| CZYLF-1 / -1A / -1B | 4 mm bore; hydraulic oil; -20 to +80 °C. The series includes separate operating-pressure ranges of 0.5-5 MPa, 3-12 MPa and 8-20 MPa. |
Larger Hydraulic Flow Paths
| Hydraulic Model | Individual Design Reference |
|---|---|
| DBD6P | 10 mm bore; working-pressure range 0-31.5 MPa; mineral hydraulic oil; -20 to +80 °C. |
| RV2-10 | 10 mm bore; hydraulic oil; listed flow range 12-114 L/min; environmental-temperature range -40 to +120 °C. |
2.5 mm cartridge relief example: cavity, sealing and retention are part of the installation. |
DBD6P outline: verify mounting dimensions and connections as well as pressure rating. |
Allow for Return Pressure and Relief Heat
Return-line back pressure
The return connection is not always at zero pressure. Back pressure can affect the opening and relieving behavior depending on the valve structure. Provide the minimum, maximum and transient outlet pressure, including any shared return-line effects.
Intermittent relief or continuous bypass
A brief pressure-limiting event and sustained bypass impose different thermal and endurance duties. Specify how long the valve relieves, how often the event occurs, and whether it must pass the full pump flow.
Estimate the Heat Load
Hydraulic power dissipated across a throttling relief path can be estimated as:
P (kW) = Δp (MPa) × Q (L/min) / 60
For an example circuit with 10 MPa pressure drop and 3 L/min bypass flow, the hydraulic power dissipated is approximately 0.5 kW. Actual oil heating depends on the duration, oil volume and heat rejection. This is a circuit calculation, not a valve performance rating.
Temperature-specific construction
Seals, spring behavior, clearances and fluid viscosity change with temperature. MH supports high-temperature micro hydraulic valve design, precision manufacture, assembly and performance validation for +200 °C duty. The named model examples above retain their own specified temperature ranges.
Make the Bench Test Follow the Circuit Duty
Pressure setting alone does not demonstrate the full duty. MH combines spring-force checks, sealing-surface and fit control, clean assembly, pressure-flow testing and opening/closing verification. The test record links the measured behavior to the fluid, temperature and outlet conditions.
| Verification Task | What the Acceptance Record Should Define |
|---|---|
| Pressure ramp up and down | Opening and closing criteria, ramp method, fluid temperature, pressure tolerance and the flow used to identify each point. |
| Relief at operating flow | Required flow, pressure at that flow, outlet back pressure and the permitted maximum pressure. Check the intended operating window rather than one isolated setting. |
| Leakage below opening / after closure | Test pressure, permitted leak rate, fluid, hold time and whether the measurement is taken before opening or after a relief cycle. |
| Durability of the control behavior | Pressure cycles, relief duration, temperature exposure and acceptable drift in opening, closure or leakage after cycling. |
Relief Valve Engineering Questions
Does a 44.5 MPa working-pressure rating mean the valve opens at 44.5 MPa?
No. Working pressure describes the stated operating pressure condition. The opening point must be specified separately unless the design data explicitly identify the two as the same.
Why can pressure continue to rise after the valve starts opening?
The valve needs sufficient opening area to pass increasing flow. The resulting pressure rise above the opening point is often described as pressure override. Evaluate the pressure at the required relief flow.
How should the bypass flow be chosen?
Use the largest flow the relief path must handle in the defined event. Depending on the circuit, this may be full pump delivery, an actuator-induced flow or thermal expansion of a trapped volume.
Will return-line pressure affect the setting?
It can, depending on the construction and drainage arrangement. Identify the actual return pressure and its variation when defining the valve and its test conditions.
Can a low-flow thermal relief replace a main hydraulic relief valve?
Not automatically. Relieving fluid expansion from a closed volume is a different duty from bypassing a pump continuously. Required flow, event duration and pressure-control behavior determine the appropriate design.
Does a check valve provide the same pressure-limiting function?
A check valve controls flow direction and reverse isolation. A relief valve opens a pressure-dependent bypass path. Some circuits require both functions, specified separately.
What helps investigate pressure drift or failure to reseat?
Record oil condition, temperature, pressure cycling, return pressure and leakage before and after the event. Seat contamination, spring variation, wear or a changed circuit condition can influence the result; the test record helps distinguish them.
Published Relief Designs and Circuit Functions
Review the corresponding detail page for the installation example. For a custom envelope or operating cycle, supply the circuit requirements rather than assuming that a similar outline has the same relieving behavior.
| Continue with | Engineering Focus |
|---|---|
| 4 mm hydraulic relief valve | CZYLF compact series and operating-pressure options. |
| 2.5 mm cartridge relief valve | Aviation hydraulic oil, cartridge format and opening-pressure references. |
| 10 mm high-pressure hydraulic relief valve | DBD6P installation and hydraulic pressure range. |
| Miniature and compact check valves | One-way isolation rather than hydraulic bypass pressure limiting. |
| Precision hydraulic and pneumatic valves | Broader fluid-control range, manufacturing and OEM program support. |
Send the Pressure-Flow Duty
Provide normal and peak inlet pressure, required opening and closure behavior, maximum pressure at bypass flow, outlet back pressure, fluid, temperature, event duration and mounting interface. Include the anticipated quantity. MH can develop the complete relief valve or manufacture an existing valve design.
As one of the most professional relief valve manufacturers and suppliers in China, we're featured by quality products and good price. Please rest assured to wholesale high quality relief valve made in China here from our factory.
relief valve, 4mm Hydraulic Relief Valve, 2 5mm Cartridge Relief Valve for Aviation Hydraulic Systems